m
About Factory

Pellentesque habitant morbi tristique ore senectus et netus pellentesques Tesque habitant.

Follow Us On Social
 

Directional control valves

DSG01 Solenoid Operated Directional Valve

 

WIDE RANGE OF MODELS–Choose the optimum valve to meet needs from a large selection available. The DSG-01 50 series solenoid operated directional valve comes with two basic models:

Standard type ——- Useable at high pressure, high flow [315Kgf/cm2 ,63L/min.]

Shockless type ——- which greatly reduces noise, which is a result of spool changeover and vibration in pipes.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
DSG -01  1 to 63 315
DSG-03 1 to 120 315

Solenoid Controlled Pilot Operated Directional Valve

 

These valves are composed of a solenoid operated pilot valves and a pilot operated slave valve. When a solenoid is energised the pilot valve directs the flow to move the spool of the slave valve, thus changing the direction of flow in the hydraulic circuit.

 

High Pressure High Flow

High pressure [315 Kgf/cm2 ] along with high flow means compact system design.

Lower pressure Drop

System energy saving increased as pressure drop of each valve has greatly reduced.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
DSHG04  1 to 63 315
DSHG-06 1 to 120 315
DSHG-10 1 to 1100 315

Pilot Operated Directional Valve

 

These valves perform a change over of spool by hydraulic pilot and shift the direction of oil flow.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
DHG-04 1 to 300 315
DHG-06 1 to 500 315
DHG-10 1 to 1100 315

Manually Operated Directional Valve

 

These valves may be used to manually shift the spool position and change the direction of oil flow.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
DMG01  1 to 35 250
DMG-03 1 to 100 250
DMG-06 1 to 500 315

Cam Operated  Directional Valve

 

These valves may be used to shift the direction of oil flow by depressing the spool by way of a cam.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
DCG01  1 to 30 210
DCG-03 1 to 100 250

In-Line Check Valve

These valves allow free flow in one direction and prevent flow in the reverse direction. Cracking pressure specified is the pressure required to open the valve and allow free flow.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
CIT-02  1 to 12 210
CIT-03 1 to 30 210
CIT-06 1 to 800 210
CIT-10 1 to 200 210

Right Angle Check Valves 

These valves allow free flow in one direction and prevent flow in the reverse direction. Cracking pressure specified is the pressure required to open the valve and allow free flow.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
CRG-03 1 to 40 250
CRG-06 1 to 125 250
CRG-10 1 to 250 250

Pilot Controlled Check Valve 

 

Pilot Controlled Check Valves These check valves allow flow in one direction and prevent flow in the reverse direction, until operated by pilot pressure to allow free reverse flow. The specified cracking pressure is required to open the valve to allow free flow direction

 

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
CPDG-06  1 to 125 250

“G” Series Shockless Type Solenoid Operated Directional Valves (Shifting Time Adjustable)

 

The G-Series Solenoid Operated Directional Valves incorporate electronic circuits to enable adjustment of the spool shifting time. A special spool shape that minimizes shock is used, shock caused by the actuator starting and stopping, as well as vibration due to oil hammering. The shifting time of conventional Solenoid Operated. Shockless, Directional Valves is constant and cannot be adjusted. As the shifting time of the G-Series valves can be adjusted, it can be set at an optional level to minimise shocks to the machine.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
G-DSG-01  1 to40 250
G-DSG-03 1 to 80 250

Double Locking Check Valves

 

These Check Valves are flow in one direction and pressure flow in reverse direction, until operated by pilot operated pressure to allow reverse flow. The specific cracking pressure required to open the valve to allow free flow direction.

Geometric Displacement

 

Series Max Flow  (lpm) Max Pressure ( bar )
DLCV-03   1 to30  160